IC60N 4P 16A Circuit Breaker Curve D with reference A9F75416 from the brand SCHNEIDER ELECTRIC
IC60N 4P 16A Circuit Breaker Curve D with reference A9F75416 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60N 4P 16A Circuit Breaker Curve D

REF
A9F75416
(0)
Free shipping
148.01 €
€148.01
€688.56
Up to -9% for professionals. Discover it.
Schneider Electric Acti9 iC60N 4P 16 A D curve thermal-magnetic circuit breaker, with thermal-magnetic protection and breaking capacity of 6 kA/10 kA for AC and DC circuits in professional installations.
Buy now and receive it between 26 and November 30
Express free delivery
Get +149 +297 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60N 4P 16A Circuit Breaker Curve D

The Schneider Electric Acti9 iC60N A9F75416 thermal-magnetic circuit breaker is a 4-pole, 16 A miniature circuit breaker designed to protect electrical circuits against overloads and short circuits. It incorporates thermal-magnetic tripping technology and a D curve, a feature especially suitable for installations with loads that can generate high inrush currents, such as motors, transformers, and other equipment with inductive components.

This model features four protected poles and can be used in AC and DC networks. It is part of Schneider Electric’s modular Acti9 iC60 range, designed for electrical distribution installations in residential, commercial, and industrial environments.

D-curve thermal-magnetic protection

The D tripping curve allows short-duration current surges higher than those typical of resistive loads to be withstood before the magnetic protection is triggered. The magnetic tripping threshold is set at 12 times the rated current, with a tolerance of ±20%.

  • Rated current: 16 A.
  • Number of poles: 4P.
  • Protected poles: 4.
  • Tripping curve: D.
  • Tripping technology: thermal-magnetic.
  • Network frequency: 50/60 Hz.
  • Network type: AC and DC.
  • Magnetic tripping threshold: 12 x In ±20%.

Breaking capacity

The Acti9 iC60N A9F75416 offers different breaking capacities depending on the operating voltage and the applicable standard. At 400 V AC, it has a rated breaking capacity Icn of 6000 A according to EN/IEC 60898-1. According to EN/IEC 60947-2, it reaches an ultimate breaking capacity Icu of 10 kA at 380-415 V AC.

  • 6000 A Icn at 400 V AC according to EN/IEC 60898-1.
  • 10 kA Icu at 380-415 V AC according to EN/IEC 60947-2.
  • 20 kA Icu at 220-240 V AC.
  • 36 kA Icu at 12-133 V AC.
  • 6 kA Icu at 440 V AC.
  • 10 kA Icu in direct current up to 250 V.

It also belongs to utilization category A and has limitation class 3 according to EN/IEC 60898-1, helping to limit the energy passing through the circuit during a short circuit.

Safety and isolation

The circuit breaker is designed to provide easy monitoring of the circuit status. It features a contact position indicator and local trip indication, making it easy to visually identify a protection trip. It is also suitable for isolation in accordance with the applicable standards.

  • Rated insulation voltage Ui: 500 V AC.
  • Impulse withstand voltage Uimp: 6 kV.
  • Contact position indicator: yes.
  • Local trip indicator: yes.
  • Device protection rating: IP20.
  • Overvoltage category: IV.
  • Pollution degree: 3.

Installation in electrical panels

The Schneider Electric A9F75416 is designed for fixed mounting on DIN rail and occupies four modules, equivalent to eight 9 mm pitches. Its modular format makes it easy to integrate into electrical distribution panels alongside other protection and control devices from the Acti9 range.

  • Mounting: fixed on DIN rail.
  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Installation depth: 44.5 mm.
  • Modular width: 4 modules.
  • Tightening torque: 2 Nm.
  • Conductor stripping length: 14 mm.
  • Maximum rigid conductor cross-section: 25 mm².
  • Maximum flexible conductor cross-section: 16 mm².

Environmental conditions

Its wide temperature range allows it to be used in a broad variety of electrical installations, always respecting the mounting and sizing conditions indicated by Schneider Electric.

  • Operating temperature: from -35 °C to +70 °C.
  • Storage temperature: from -40 °C to +85 °C.

Standards

The Acti9 iC60N A9F75416 thermal-magnetic circuit breaker is designed in accordance with the main standards applicable to low-voltage circuit breakers, including EN/IEC 60898-1 and EN/IEC 60947-2.

A professional solution for protecting 16 A circuits that require four poles and a D curve, combining overload and short-circuit protection, high breaking capacity, and the modular format characteristic of Schneider Electric’s Acti9 range.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F75416
SKU
SCHFC11DD19
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
16 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi