The ABB OVR T2-T3 1N 20-275 P QS surge protector, reference 2CTB803972R1200, is a Type 2+3 transient overvoltage protection device designed to protect electrical installations and sensitive equipment against surges caused by switching operations on the network or indirect lightning effects. It features a 1P+N configuration, maximum continuous operating voltage of 275 V AC, maximum discharge current of 20 kA, and a protection level Up of up to 1.4 kV.
It is part of ABB's OVR surge protector range and uses QuickSafe technology. Its plug-in design makes maintenance and cartridge replacement easy, while the visual status indicator allows quick checking of the protector's condition. It is designed for DIN rail mounting and occupies only 2 modules.
The ABB 2CTB803972R1200 combines the features of Type 2 and Type 3 surge protection devices. This design makes it suitable for limiting transient overvoltages and providing a reduced residual voltage level for the protection of sensitive electrical and electronic equipment.
ABB recommends installing Type 2+3 protectors as close as possible to the sensitive loads to be protected, correctly coordinating them with the surge protection devices installed upstream.
The protector has a 1P+N configuration, with two protected poles, and is intended for low-voltage installations with TT and TN-S distribution systems.
This configuration makes it especially suitable for single-phase circuits where it is necessary to limit surges between phase, neutral and earth.
ABB specifies for this protector a maximum discharge current Imax of 20 kA with an 8/20 µs waveform. This capacity allows the device to divert high-intensity transient currents to earth and limit the voltage reaching downstream connected equipment.
The nominal discharge current In is 5 kA with an 8/20 µs waveform, according to the technical documentation for the range.
Reference 2CTB803972R1200 has a maximum continuous operating voltage Uc of 275 V AC. It is designed for low-voltage networks with a system nominal voltage of 230/400 V AC.
The surge protection level Up is 1.4 kV. This parameter indicates the maximum residual voltage level that may appear under certain test conditions during protector operation.
ABB also specifies a protection level of 0.9 kV between phase and neutral, helping to improve the protection of sensitive equipment connected to the installation.
The OVR T2-T3 incorporates ABB QuickSafe technology, developed for the surge protection devices in the OVR range. This solution is designed to provide safe disconnection of the protective element when it reaches the end of its service life.
The device also features a visual status indicator, which allows you to visually check whether the protector is still operational and simplifies inspection and maintenance tasks in the electrical panel.
The P version of the ABB OVR T2-T3 corresponds to a plug-in design. The protective module can be replaced without having to completely replace the installed base, simplifying maintenance work.
This format is especially practical in installations where it is desirable to reduce intervention times after a protector has reached the end of its service life.
Reference 2CTB803972R1200 does not include a remote signaling contact. ABB identifies variants equipped with remote signaling by the letters TS in the product designation.
This model therefore provides local checking via its visual status indicator. For applications requiring remote monitoring, the corresponding ABB variant equipped with a TS contact must be selected.
The protector is designed to be installed directly on a DIN rail in modular electrical panels. Its net width is 35.6 mm, equivalent to approximately 2 DIN modules.
The ABB OVR T2-T3 1N 20-275 P QS has an IP20 protection rating and is designed to be installed inside a suitable electrical enclosure or panel.
According to the technical documentation, it can operate up to an altitude of 5,000 meters without derating.
ABB specifies that OVR surge protectors must have appropriate overcurrent protection by means of a circuit breaker or fuse, always taking into account coordination with the main upstream protection.
For Type 2+3 protectors of 20 kA and Uc 275 V, the ABB catalog specifies a curve C circuit breaker of up to 63 A maximum as a reference and recommends, for the standard configuration, an ABB S200 C10 MCB. The final selection must be made according to the specific conditions of the installation and the manufacturer's coordination tables.
The ABB 2CTB803972R1200 can be used in residential installations, commercial buildings and industrial applications where sensitive equipment needs protection against transient overvoltages.
Loads that can benefit from coordinated surge protection include electronic equipment, automation systems, household appliances, electronic lighting, IT systems, HVAC equipment and other sensitive receivers.
The ABB OVR T2-T3 1N 20-275 P QS is developed in accordance with IEC 61643-11 and EN 61643-11 standards applicable to surge protection devices connected to low-voltage electrical networks.
The ABB OVR T2-T3 1N 20-275 P QS 2CTB803972R1200 surge protector offers a compact solution for protecting sensitive electrical and electronic equipment against transient overvoltages. Its Type 2+3 combination, 1P+N configuration for TT and TN-S networks, Uc of 275 V, Imax of 20 kA, Up of 1.4 kV, QuickSafe technology and plug-in cartridge make it easy to integrate into residential, commercial and industrial electrical panels.